Reliability of measurements derived from the palpation method of a software for postural evaluation: does clinical experience matter?

Authors

  • Isabella da Silva Almeida Catholic University of Brasilia
  • Larissa Pitanga Barreto Catholic University of Brasilia
  • Letícia de Souza Andrade Catholic University of Brasilia
  • Caio Victor Sousa Catholic University of Brasilia
  • Yomara Lima Mota Catholic University of Brasilia

DOI:

https://doi.org/10.1590/1980-0037.2018v20n6p515

Abstract

The postural evaluation software (SAPO) has been used as a valuable tool for the analysis of postural alterations, however, such a tool depends on palpation performed by the evaluator. The aim of the present study was to evaluate the inter- and intra-examiner reliability of experienced and inexperienced examiners in measurements derived from the palpation method, and its possible influence on measurements obtained by SAPO. Nine evaluators participated in the study, which were divided into three groups according to experience with respect to palpation (GI: inexperienced group, GSE: semi-experienced group and GE: experienced group). Each evaluator performed the postural analysis of 10 volunteers, which were photographed in orthostatic position, following the SAPO recommendations. The intra-examiner reliability analysis indicated that all three groups had higher, good and moderate mean correlation values for each examiner than low correlations. In the inter-examiner reliability assessment, GE and GSE groups exhibited higher correlation values. The intra-class correlation coefficient, in the single-measure analysis, presented correlation coefficients <0.70 in 9 of the variables analyzed, indicating non-significant correlation. It was concluded that the measures analyzed by SAPO have high intra-examiner reliability. However, regarding inter-examiner reliability, the group composed of inexperienced evaluators presented lower values, suggesting that the experience time may have influenced the inter-examiner reliability regarding postural evaluation.

Author Biographies

Isabella da Silva Almeida, Catholic University of Brasilia

Catholic University of Brasilia

Larissa Pitanga Barreto, Catholic University of Brasilia

Catholic University of Brasilia

Letícia de Souza Andrade, Catholic University of Brasilia

Catholic University of Brasilia

Caio Victor Sousa, Catholic University of Brasilia

Catholic University of Brasilia

Yomara Lima Mota, Catholic University of Brasilia

Catholic University of Brasilia

References

Farias NC, Rech I, Ribeiro BG, Oliveira CS, Menna W, Albuquerque CE, et al. Avaliação postural em hemiparéticos por meio do software SAPO – Relato de caso. Conscientiae Saúde 2009;8(4):649-54.

Iunes DH, Bevilaqua GD, Oliveira AS, Castro FA, Salgado HS. Análise comparativa entre avaliação postural visual e por fotogametria computadorizada. Rev Bras Fisioter 2009;13(4):308-15.

Downey BJ, Taylor NF, Niere KR. Manipulative physiotherapists can reliably palpate nominated lumbar spinal levels. Man Ther 1999;4(3):151-156.

Wadie IN, Michael AS, Shiraz IM, Vivian MD, Alan A, Sibylle R, et. al. Content validity of manual spinal palpatory exams - A systematic review. Altern Med 2003;3(1):1-14.

Moran R, Ljubotenski E. Reliability of visual assessment for lumbar curves in standing: Does clinical experience matter? Int J Osteopath Med 2006;9(1):27-46.

Haneline MT, Morgan YD. A review of intraexaminer and interexaminer reliability of static spinal palpation: a literature synthesis. J Manipulative Physiol Ther 2009;32(5):379-86

Fedorak C, Ashworth N, Marshall J, Paull H. Reliability of the visual assessment of cervical and lumbar lordosis: How good are we? Spine 2003;28(16):1857-9.

Najm WI, Seffinger MA, Mishra SI, Dickerson VM, Adams A, Reinsch S, et al. Content validity of manual spinal palpatory exams - A systematic review. BMC Complement Altern Med 2003;3:1.

Stolfi J, Moura J.A. Confiabilidade intra e interexaminadores de medidas fotogramétricas para análise do alinhamento vertical da coluna verteral. Rev Aten Saúde 2014;12(41):29-36

McKenzie AM, Taylor NF. Can physiotherapists locate lumbar spinal levels by palpation? Physiotherapy 1997;83(5):235-9

Castro PCG, Lopes JAF. Avaliação computadorizada por fotografia digital, como recurso de avaliação na Reeducação Postural Global. Acta Fisiátrica 2003;10(2):83-88.

Sato TO, Vieira ER, Gil Coury HJC. Análise da confiabilidade de técnicas fotométricas para medir a flexão anterior de tronco. Rev Bras Fisioter 2003;7(1):25-31.

Döhnert MB, Tomasi E. Validade da fotogrametria computadorizada na detecção de escoliose idiopática adolescente. Rev Bras Fisioter 2008;12(4):290-7.

Sacco ICN, Alibert S, Queiroz BWC, Pripas D, Kieling I, Kimura AA. Confiabilidade da fotogametria em relação a goniometria para a avaliação postural de membros inferiores. Rev Bras Fisioter 2007;11(5):411-7.

Ferreira EAG, Duarte M, Maldonado EP, Burke TN, Marques AP. Postural assessment software (PAS/SAPO): validation and reliability. Clinics 2010;65(7):675-81.

Braz RG, Goes FPC, Carvalho GA. Confiabilidade e validade de medidas angulares por meio do software para avaliação postural. Fisioter Mov 2008;21(3):117-126.

Ferreira EA, et al. Quantitative assessment of portural alignment in Young adults based on photographs of anterior, posterior, and lateral views. J Manipulative Physiol Ther 2011;34(6):371-80.

Duarte M, Ferreira EA, Maldonado EP, Freitas AZ. Documentação sobre o SAPO – Software de Avaliação Postural. 2005. Disponível em: http://demotu.org/sapo/> [2017 fev 20].

Bland J.M, Altman D.G. Statistical methods for assessing agreement between two methods for clinical measurement. Lancet 1986, 8:307-10.

Souza JA, Pasinato F, Basso D, Corrêa ECR, da Silva AMT. Biofotogrametria confiabilidade das medidas do protocolo do software para avaliação postural (SAPO). Rev Bras Cineantropom Desempenho Hum 2011,13(4):299-305.

Santos MM, Silva MPC, Sanada LS, Alves CRJ. Análise postural fotogramétrica de crianças saudáveis de 7 a 10 anos: confiabilidade interexaminadores. Rev Bras Fisioter 2009, 13(4):350-355

Nery, PB. Análise da confiabilidade intra e interexaminador do software de avaliação postural – SAPO em escolares do município de Ribeirão Preto –SP. [Dissertacão - Escola de Enfermagem de Ribeirão Preto da Universidade de São Paulo]. Ribeirão Preto (SP): Universidade de São Paulo; 2009.

Glaner MF, Mota YL, Viana ACR, Santos MC. Fotogrametria: Fidedignidade e falta de objetividade na avaliação postural. Motrici 2012, 8(1):78-85.

Downloads

Published

2018-12-31

Issue

Section

Original Articles