Validación del monitor de actividad física de TrackHealth

Autores/as

DOI:

https://doi.org/10.1590/1980-0037.2022v24e83854

Palabras clave:

Comparison, Accelerometry, Motion, Raw data

Resumen

This is a quantitative methodological study for the validation of a research instrument. It aimed to validate the data from the TrackHealth accelerometry device. The sample consisted of 30 adult individuals of both sexes selected by convenience who met the inclusion and exclusion criteria. The physical activity monitors used for the research protocol were the ActiGraph® wGT3X-BT triaxial accelerometer and the TrackHealth accelerometer (TH). The activity protocol consisted of 4 (four) activities (walking at 4.8 and 6.4 km h¹ and running at 9.7 and 12 km h¹) performed in the laboratory, on an Ibramed treadmill, lasting 5 (five) minutes at each stage. A difference was found between the raw acceleration data of the two devices, however the TrackHealth device showed higher sensitivity at speeds of 4.8 and 6.4 km/h, and a high level of agreement (2.7-2.8%) at the initial speeds of the magnitude vectors. However, there is still a need for improvement in the functioning of the device, so that TrackHealth can be commercialized.

Citas

Knuth AG, Malta DC, Cruz DK, Castro AM, Fagundes J, Sardinha LM, et al. Description of the countrywide physical activity network coordinated by the Brazilian Ministry of Health: 2005-2008. J Phys Act Health. 2010;7( Suppl 2):S253-8. doi: 10.1123/jpah.7.s2.s253. PMID: 20702913.

Chen KY, Bassett DR Jr. The technology of accelerometry-based activity monitors: current and future. Med Sci Sports Exerc. 2005 Nov;37(11 Suppl):S490-500. doi: 10.1249/01.mss.0000185571.49104.82. PMID: 16294112.

Motl RW, Snook EM, Agiovlasitis S, Suh Y. Calibration of accelerometer output for ambulatory adults with multiple sclerosis. Arch Phys Med Rehabil. 2009;90(10):1778-84. doi: 10.1016/j.apmr.2009.03.020. PMID: 19801071.

Serra MC, Balraj E, DiSanzo BL, Ivey FM, Hafer-Macko CE, Treuth MS, Ryan AS. Validating accelerometry as a measure of physical activity and energy expenditure in chronic stroke. Top Stroke Rehabil. 2017;24(1):18-23. doi: 10.1080/10749357.2016.1183866.

Montoye AHK, Moore RW, Bowles HR, Korycinski R, Pfeiffer KA. Reporting accelerometer methods in physical activity intervention studies: a systematic review and recommendations for authors. Br J Sports Med. 2018;52(23):1507-1516. doi: 10.1136/bjsports-2015-095947.

Sasaki JE, John D, Freedson PS. Validation and comparison of ActiGraph activity monitors. J Sci Med Sport. 2011;14(5):411-6. doi: 10.1016/j.jsams.2011.04.003.

Bassett DR, Troiano RP, McClain JJ, Wolff DL. Accelerometer-based physical activity: total volume per day and standardized measures. Med Sci Sports Exerc. 2015;47(4):833-8. doi: 10.1249/MSS.0000000000000468

Ruiz JR, Ortega FB, Martínez-Gómez D, Labayen I, Moreno LA, De Bourdeaudhuij I, et al. Objectively measured physical activity and sedentary time in European adolescents: the HELENA study. Am J Epidemiol. 2011;174(2):173-84. doi: 10.1093/aje/kwr068

Silva I, Sasaki J, Gonçalves P. Mensuração da atividade física e tempo sedentário por meio de acelerômetros: cenário atual, perspectivas e demandas futuras. Rev Bras Ativ Fís Saúde 2016;21(4):293–6.

Freedson PS, Melanson E, Sirard J. Calibration of the Computer Science and Applications, Inc. accelerometer. Med Sci Sports Exerc. 1998;30(5):777-81. doi: 10.1097/00005768-199805000-00021.

John D, Morton A, Arguello D, Lyden K, Bassett D. "What Is a Step?" Differences in How a Step Is Detected among Three Popular Activity Monitors That Have Impacted Physical Activity Research. Sensors (Basel). 2018;18(4):1206. doi: 10.3390/s18041206.

Miller J. Accelerometer Technologies, Specifications and Limitations. In Proceedings of Internationational Conference on Ambulatory Monitoring and Physical Activity Measurement, Amherst, MA, USA, 17–19 June 2013.

Matthew CE. Calibration of accelerometer output for adults. Med Sci Sports Exerc. 2005;37(11 Suppl):S512-22. doi: 10.1249/01.mss.0000185659.11982.3d.

Paul DR, Kramer M, Moshfegh AJ, Baer DJ, Rumpler WV. Comparison of two different physical activity monitors. BMC Med Res Methodol. 2007;7:26. doi: 10.1186/1471-2288-7-26.

Descargas

Publicado

2023-02-23